If you feel your bill is to high, call the water dept and tell them you want your meter checked. We recently bought a new house in the same neighborhood as our old house. What’s going on with my boiler? This article explains how to identify the size of the water meter and supply line. Determine average minimum pressure in the street main. How can we shut off the water supply to my house. }×w|o6èM‘/ìj*Ȇ‘ßäT…–v}�¬7™-º¦ÓïùQ¿³t‚hl¹ÕT p0*TÁqƒ. I am currently showing a 2" water meter on my plan, but my client wants to use a 1" water meter. Badger or Sensus makes them. To determine the correct size, please provide the following essential information. By joining you are opting in to receive e-mail. ? The calculated water usage for a new Carwash Facility that we are developing is about 3,350 GPD. We recently bought a new house in the same neighborhood as our old house. You can sign in to vote the answer. Can we have a smaller meter installed by a plumber? yes, downsizing a meter can be done and will be cheaper for the size plays a large cost in your bill. A 1 inch pipe will supply around 25-28 gpm continuously with minimum pressure loss. To determine the water meter fee, the water development fee and the sewer connection fee, we must know the size of the water meter required for the residence. Finally, select the meter size by calculating flow rates. It turns out that the house that we bought has a 2" water meter and our old house has a 5/8" water meter. Or is there a reason the city would require such a large meter on a house? some thoughts from the top of my head: Contact the manufacturer of the water meter. In that case you have two choices. Just what plumbing you would find an a average 4 bedroom, 3 bathroom house. It will probably not be relevant whether or not a 1" or 2" will work. Note: This question is purely about things to consider when determining the right size of our water meter. I would be contacting the water supplier to get that changed. Please let us know here why this post is inappropriate. many types are available on the market. footage wise but not enough to make that kind of a jump. The new house that we bought is larger sq. Richard A. Cornelius, P.E.WWW.amlinereast.com, Remember, amateurs built the ark...professionals built the Titanic. It will be something like ¾” or 1”, in most residential cases. water meter sized is based on demand required by the fixtures consuming water. water meter sized is based on demand required by the fixtures consuming water. Town codes usually dictate what size meter they should have. What is the standard height of sockets, lighting switches, and the main switch from the ground floor? Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. These design issues lead to increase in time and cost of production leading to delay in time to market and reduced profits for the organization. Domestic water meters comes in three different models including Electromagnetic, Mechanical Insert, and Ultrasonic. The second step is to find out the size line you have as a service line.The size can run from ¾” inch to 1”-1/2” inch for residential or domestic purposes. 3/4" Water Meter (standard) The standard 3/4" water meter has a lay length of 9" from then ends of the threaded spuds. The water meter will be designed at a certain size diameter and a certain PSI. I work for a water company and there are minimum bills for each size meter. The vast majority of properties in the UK have a 1/2in supply although new supplies and updates are having 3/4in as it has been found that some of the new combination boilers need the larger supply to perform correctly. The water meter will be designed at a certain size diameter and a certain PSI. typically a consulting firm will look: at the number of "water service fixture units (wsfu),' the gpm required by each fixture, where these fixtures are located and the head loss. Each has a different measuring mechanism, but all indicate the same thing. Each fixture is given a value based on typical water use. This white paper will go through the various assembly level issues, which need to be tackled by various organizations on a regular basis. This can be obtained from Water Company or by test. You probably need a turbo meter: AWWA has specifications on cold water meters, As I recall a 1" is good for 50 gpm peak, 1.5" is 100 gpm, and 2" is 160 gpm,  manufactorers will rate them for slightly higher flows. Thank you for helping keep Eng-Tips Forums free from inappropriate posts.The Eng-Tips staff will check this out and take appropriate action. The pipework can always be reduced to accommodate a smaller meter. So we were surprised to see that our base rate on our water bill jumped from 4.00 to 22.40. Therefore, either 5/8" x 1/2" or 5/8" x 3/4" may be marked with just 5/8" on the body and register which designated the internal capacity, not the thread size. *Eng-Tips's functionality depends on members receiving e-mail. Follow the instructions to determine the water meter size that will be required for your site. Based on the projected flow of 3,350 GPD how can I determine what size water meter I need to use for this project. Copyright © 1998-2020 engineering.com, Inc. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. 1. The benefits of cost and time savings using effective collaborative mechanisms at the right time have been highlighted in this white paper. It turns out that the house that we bought has a 2" water meter and our old house has a 5/8" water meter. Meter size Who can install it 20 mm For a locked and tagged water service (like the one pictured on the next page) Sydney Water 20 mm to 50 mm light duty For a standard water service Sydney Water or a licensed plumber 50 mm to 300 mm heavy duty For a standard water service The easiest might be to simply call your water company and ask. How do you think about the answers? meters are generally installed by the city, and size is determined by the size of the main water supply line coming into you house. -Steve. So we were surprised to see that our base rate on our water bill jumped from 4.00 to 22.40. If these requirements are not addressed at the design stage, lot of time is spent in design iteration when the design reaches the die caster. ݺ‚„°—0ú=D p?ô&óÄ~¯;Ø‘c÷¼ĞŒg5LÈá`L¨‚ãÄû™ 7™Fıå"mgÙÇ£nÏ«g…�2¡ The only difference from the old house is one more full bathroom and a sink in the laundry room. Assembly level constraints need to be satisfied before the design can move downstream. Call the water provider, they will send you a service application. typically a consulting firm will look: at the number of "water service fixture units (wsfu),' the gpm required by each fixture, where these fixtures are located and the head loss. How bad a state will my guttering be when I never cleaned it in five and a half years? Sometimes it is stamped on the metal below the dial face. Registration on or use of this site constitutes acceptance of our Privacy Policy. Still have questions? Water Closet, 1.6 GPF Gravity Tank: 1/2: 2.5: 2.5: Water Closet, 1.6 GPF Flushometer Tank: 1/2: 2.5: 2.5: Water Closet, Greater Than 1.6 GPF Gravity Tank: 1/2: 3.0: 5.5 My smoke detector went off for no apparent reason? Sometimes it’s not there or so dirty you can’t find it. Join your peers on the Internet's largest technical engineering professional community.It's easy to join and it's free. How is a water meter size determined? Many meters have their size located directly below the gallon count. the larger the building and its fixtures, the larger the meter size... you just specified the new home has more bathrooms, have a licensed plumber size the fixtures based on demand and advise you the appropriate course of action -. A 2 inch pipe will supply around 90-100 gpm continuously with minimum pressure loss. It turns out that the house that we bought has a 2" water meter and our old house has a 5/8" water meter. This does NOT permit the violation of any section of any federal, state or local regulations. Already a member? How a water meter works depends on the style,purpose, and size of the meter.